| Part Description | |||
| Part Number | Application | Jacket | Code |
| TCOM-240 | Outdoor | PE | 55017 |
| TCOM-240-FR | Indoor-Riser CMR | FRPE | 55023 |
| Environmental Specifications | ||
| Performance Property | F | C |
| TCOM-240 | Outdoor | PE |
| TCOM-240-FR | Indoor-Riser CMR | FRPE |
| Construction Specifications | |||
| Inner Conductor | Material | In. | (mm) |
| Description | Solid BC | 0.056 | (1.42) |
| Dielectric | Foam PE | 0.150 | (3.81) |
| Outer Conductor | SPC Strip Braid | 0.160 | (4.06) |
| Overall Braid | TC Braid over Al tape | 0.188 | (4.78) |
| Jacket | (see table) | 0.240 | (6.10) |
| Mechanical Specifications | |||
| Performance Property | Units | US | (metric) |
| Bend Radius: installation | in. (mm) | 0.75 ( | 5 (19.1) |
| Bend Radius: repeated | in. (mm) | 2.5 | (63.5) |
| Bending Moment | ft-lb (N-m) | 0.25 | (0.34) |
| Weight | lb/ft (kg/m) | 0.045 | (0.07) |
| Tensile Strength | lb (kg) | 80 | (36.3) |
| Flat Plate Crush | lb/in. (kg/mm) | 20 | (0.36) |
| Mechanical Specifications | |||
| Performance Property | Units | US | (metric) |
| Velocity of Propagation | % | 84 | |
| Dielectric Constant | NA | 1.42 | |
| Time Delay | nS/ft (nS/m) | 1.21 | (3.97) |
| Impedance | ohms | 50 | |
| Capacitance | pF/ft (pF/m) | 24.2 | (79.4) |
| Inductance | uH/ft (uH/m) | 0.060 | 0 (0.20) |
| Shielding Effectiveness | dB | >100 | |
| DC Resistance | |||
| Inner Conductor | ohms/1000ft (/km) | 3.2 | (10.5) |
| Outer Conductor | ohms/1000ft (/km) | 2.06 | (6.8) |
| Voltage Withstand | Volts DC | 1500 | |
| Jacket Spark | Volts RMS | 5000 | |
| Peak Power | kW | 5.6 | |
| Passive Intermod | dBc | -155 | |